Seleccionar valores de las listas desplegables para configurar las referencia.
System/Body
-- Escoja una opción --
P (Vacuum Pump System, Single Unit)
Q (Vacuum Pump System, for Manifold)
A (Ejector System, Single Unit, Silencer Exhaust)
B (Ejector System, Single Unit, Port Exhaust)
C (Ejector System, for Manifold, Common Silencer Exhaust)
F (Ejector System, for Manifold, Individual Port Exhaust)
G (Ejector System, Single Unit, High-noise Reduction, Silencer Exhaust)
H (Ejector System, for Manifold, High-noise Reduction, Silencer Exhaust)
Nozzle Size
-- Escoja una opción --
00 (Vacuum Pump System)
07 (Ejector System, ø0.7 Nominal Nozzle Size)
10 (Ejector System, ø1.0 Nominal Nozzle Size)
12 (Ejector System, ø1.2 Nominal Nozzle Size)
15 (Ejector System, ø1.5 Nominal Nozzle Size)
Valves
-- Escoja una opción --
K (Supply Valve; N.C., Release Valve; N.C.)
J (Supply Valve; N.C., Release Valve; None)
R (Supply Valve; Self-holding Release Valve Linked, Release Valve; N.C.)
N (Supply Valve; None, Release Valve; None)
Rated Voltage
-- Escoja una opción --
5 (24 VDC)
6 (12 VDC)
0 (When Combination of Supply Valve and Release Valve is N)
Sensor/Switch for Vacuum Specs.
-- Escoja una opción --
P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V)
T (Pressure Sensor, -100 to 100, Analog Output 1 to 5 V)
A (Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs, Unit Selection Function)
B (Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs, SI Unit Only)
C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Unit Selection Function)
D (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, SI Unit Only)
E (Digital Pressure Switch for Vacuum, -100 to 100, NPN 2 Outputs, Unit Selection Function)
F (Digital Pressure Switch for Vacuum, -100 to 100, NPN 2 Outputs, SI Unit Only)
H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, Unit Selection Function)
J (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, SI Unit Only)
K (Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, NPN 1 Output, Unit Selection Function)
Q (Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, NPN 1 Output, SI Unit Only)
R (Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, PNP 1 Output, Unit Selection Function)
S (Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, PNP 1 Output, SI Unit Only)
N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum)
Valves/Switch for Vacuum Conn. Specs.
-- Escoja una opción --
C (Common Wiring, Plug-in for Manifold)
C1 (Common Wiring, Plug-in for Manifold)
L (L-type Plug Connector)
L1 (L-type Plug Connector)
L2 (L-type Plug Connector)
L3 (L-type Plug Connector)
W (w/Lead Wire for Switch with Energy Saving Function)
Y [Non-valve (w/o Supply, Release Valve)]
Y1 [Non-valve (w/o Supply, Release Valve)]
N ("N" is selected for Combination of Supply Valve and Release Valve and Pressure Sensor, Digital Pressure Switch for Vacuum)
Vacuum, V Port
-- Escoja una opción --
06 (Metric Size, ø6 One-touch Fitting)
08 (Metric Size, ø8 One-touch Fitting)
07 (Inch Size, ø1/4" One-touch Fitting)
09 (Inch Size, ø5/16" One-touch Fitting)
Optional Specs. 1
-- Escoja una opción --
Ninguno
B [One Bracket for Mounting Single Unit, (Mounting Screw Attached)]
BC (B+C)
BCD (B+C+D)
BCDJ (B+C+D+J)
BCJ (B+C+J)
BD (B+D)
BDJ (B+D+J)
BJ (B+J)
C (Pump System PE Port Female Thread Specification)
CD (C+D)
CJ (C+J)
CDJ (C+D+J)
D [w/Individual Release Pressure Supply, (PD) Port Type]
DJ (D+J)
J (Vacuum Break Flow Adjustment Needle, Round Lock Nut Type)
Optional Specs. 2
-- Escoja una opción --
Ninguno
K (Vacuum Break Flow Adjustment Needle, Screwdriver Operation Type)
KL (K+L)
KLP (K+L+P)
KLPW (K+L+P+W)
KLW (K+L+W)
KP (K+P)
KPW (K+P+W)
KW (K+W)
L (Manifold Individual Supply Specification)
LP (L+P)
LPW (L+P+W)
LW (L+W)
P (Manifold Common Release Pressue Supply Specification)
PW (P+W)
W (w/Exhaust Interference Prevention Valve)
Opciones en: Gris no son compatibles con cualquier otro valor seleccionado. Rojo tienen conflictos con otro valor seleccionado. Ambar no se recomiendan.